5. Check EVAP Canister Vent Control Valve Output Signal Circuit For Open And Short
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check harness continuity between ECM terminal 158 and EVAP canister vent control valve terminal 2. Refer to WIRING DIAGRAM .
Continuity should exist.
- Also check harness for short to ground and short to power.
OK or NG
- OK: GO TO 7. CHECK RUBBER TUBE FOR CLOGGING .
- NG: GO TO 6.