ASCD Actuator
- Disconnect vacuum hose from ASCD actuator.
- Connect the hose of hand vacuum pump to ASCD actuator.
Apply -40 kPa (-0.41 kg/cm 2 , -5.8 psi) vacuum to ASCD actuator with hand vacuum pump .
ASCD wire should move to pull throttle drum .
Wait 10 seconds and check for decrease in vacuum pressure .
Vacuum pressure decrease: Less than 2.7 kPa (0.028 kg/cm 2 , 0.39 psi)