Diagnostic Procedure
- INSPECTION START
Erase (1st trip) DTCs. Refer to "HOW TO ERASE EMISSION-RELATED DIAGNOSTIC INFORMATION ".
- : GO TO 2.
- CHECK GROUND TERMINALS
Check ground terminals for corroding or loose connection.
Refer to HOW TO PERFORM EFFICIENT DIAGNOSIS FOR AN ELE , CIRCUIT INSPECTION , GROUND INSPECTION .
OK or NG
- OK: GO TO 3.
- NG: Repair or replace.
- SEARCH FOR ELECTRICAL INCIDENT
Perform GI-26"How to Perform Efficient Diagnosis for an Electrical Incident""INCIDENT SIMULATION TESTS".
OK or NG
- OK: GO TO 4.
- NG: Repair or replace.
- CHECK CONNECTOR TERMINALS
Refer to HOW TO CHECK TERMINAL "HOW TO PROBE CONNECTORS & HOW TO CHECK ENLARGED CONTACT SPRING OF TERMI .
OK or NG
- OK: INSPECTION END