(Driven Pulley Pressure Sensor Removal And Installation)
ABBREVIATED PROCEDURE
| Work | H/W | Tightening torque N.m (kgf.m/lb-ft) | SST/Equipment | Chemical | etc | |
|---|---|---|---|---|---|---|
|
||||||
| 1 | Disconnect the negative (-) battery cable | - | - | - | - | - |
| 2 | Remove the engine room under cover (Refer to Engine Mechanical System - "ENGINE ROOM UNDER COVER ") |
- | - | - | - | - |
| 3 | Remove the IVTF drain plug allow the fluid to drain out and then reinstall the drain plug | - | - | - | - | Refer to appropriate service information |
| 4 | Remove the valve body cover after removing the bolts | - | - | - | - | Refer to appropriate service information |
| 5 | Remove the IVTF filter after removing the bolts | - | - | - | - | - |
| 6 | Disconnect the driven pulley pressure sensor connector | - | - | - | - | - |
| 7 | Remove the driven pulley pressure sensor | - | - | - | - | - |
|
||||||
| 1 | Install the driven pulley pressure sensor | - | 11.8 - 13.7 (1.2 - 1.4/8.7 - 10.1) | - | - | Refer to appropriate service information |
| 2 | Connect the driven pulley pressure sensor connector | - | - | - | - | - |
| 3 | Install the IVTF filter | Bolt | 9.8 - 11.8 (1.0 - 1.2/7.2 - 8.7) | - | - | - |
| 4 | Install the oil pan | Bolt | 9.8 - 11.8 (1.0 - 1.2/7.2 - 8.7) | - | - | Refer to appropriate service information |
| 5 | Check the IVTF level after refilling the intelligent variable transmission with fluid | - | - | - | - | Refer to appropriate service information |
| 6 | Check for leakage of IVT fluid from engine start | - | - | - | - | - |
| 7 | Install the engine room under cover (Refer to Engine Mechanical System - "ENGINE ROOM UNDER COVER ") |
- | - | - | - | - |
|
||||||
|
||||||