Initializing Method Of The Safety Power Window
- Initializing of Battery Connection
When the battery power is removed for over 5 minutes, safety power window switch need the initializing.
- Power window operation before initializing
- Manual-Up/Down function is available
- Auto-Up function is not available
(When holding the auto-up/down switch, window is operated as a manual-up/down.)
- Initializing method
Close the window in window open position, and hold the switch in window full closed position for over 0.2 seconds.
(If closing the window is started in window full closed position, initializiation could fail.)
- If
the safety power window is initialized while in jamming status, the following conditions could occur:
- Safety function is not available
- Power window operation before initializing
- Initializing of fail safe mode
- If the window moved by compulsion and motor have a problem, power window switch could be entering the fail safe mode for user's safety.
- Power window operation in fail mode
- Auto/Manual-Down function is available
- Auto/Manual-Up function is not available
(When auto/manual-up is operated, the window rises 20mm and stops. )