Mike's Workshop Manuals: Service manuals for every vehicle
Home >> Hyundai >> 2021 >> Veloster 2.0, Automatic Trans >> Repair and Diagnosis >> Engine Performance >> System >> Engine Control System Diagnosis - 2.0L (3 Of 3) >> DTC P2196-00: O2 Sensor Signal Stuck Rich (Bank 1 Sensor 1) >> Component Inspection >> Ho2S

Component Inspection: Ho2S

  1. Visually/physically inspect the following items:
    • Ensure that the HO2S is securely installed.
    • Silicon contamination. This contamination will be indicated by a white powdery coating on the portion of the sensor exposed to the exhaust stream and this will result in a but false (high) voltage signal
    • Fuel, engine coolant or oil contamination
    • Use of improper sealant
    • If contamination is evident on the HO2S, Fix the source of the sensor contamination before replacing the sensor to prevent future contamination. Go to "VERIFICATION OF VEHICLE REPAIR " procedure.
  2. Was a problem found in any of the above areas?

    YES 

    NO 

    • Substitute with a known-good component and check for proper operation. If the problem is corrected, replace component and then go to "VERIFICATION OF VEHICLE REPAIR " procedure.