| DTC Strategy |
- Characteristic Monitoring
|
- Poor Connector Connection
- Faulty Upstream O2 Sensor
|
| Enable Condition |
Case 1 |
|
| Case 2 |
- No Fuel Cut Off
- No Full Load
- No catalyst overheating protection
- Battery voltage higher than 11V and lower than 16V
|
| Threshold Value |
Case 1 |
- Upstream Lambda (lean) over 1.1 and Downstream O2 signal voltage over 0.75V (rich) and lambda controller in limit (50%)
|
| Case 2 |
- Lambda value over 0.9 when lambda setpoint is 0.8
|
| Diagnostic Time |
Case 1 |
- 5 to 100 sec. depending on intake air mass
|
| Case 2 |
- 10 sec. after lambda setpoint shift to corresponding side
|
| MIL ON Condition |
|