Repair Procedures: Installation
NOTE:
Before installing, check that the shift lever in the "N" position.
- Install the shift lever assembly (A).
Tightening torque:
9.8 ~ 13.7 N.m (1.0 ~ 1.4 kgf.m, 7.2 ~ 10.1 lb-ft)
- Install the shift cable (A).NOTE: Insert the shift cable after checking the direction of projection (B) to prevent wrong assembly.
- Connect the main connector (A).
- Install the floor console assembly.
(Refer to "Floor Console ")
- Install the shift lever knob assembly.
- Install the knob assembly (A) and then fixing the pin (B).
- Install the cover (A).
CAUTION: Check that operating surely at each range of the inhibitor switch corresponding to each position of shift lever.