PODS-F Zeroing Procedure

You should perform PODS-F Re-zero procedure after service or replacement about all part of the passenger seat. (Not included full seat assembly)

  1. Ignition "OFF", connect GDS.
  2. Ignition "ON" & Engine "OFF", select Airbag system and "PODS-F Reset" mode.
    Fig 1: Screen Display - PODS-F Reset Mode
    G12125507Courtesy of HYUNDAI MOTOR AMERICA
  3. The GDS will show the two PODS-F Zeroing function steps.
    1. Erase PODS-F diagnostic codes.
    2. PODS-F initialization.
    Fig 2: Screen Display - PODS-F Initialization
    G12125508Courtesy of HYUNDAI MOTOR AMERICA
    CAUTION: This step must be done PODS-F re-zero, when the front passenger seat is empty.
  4. The PODS-F initialization procedure will be performed.
Fig 3: Screen Display - PODS-F Initialization (1 Of 2)
G12125509Courtesy of HYUNDAI MOTOR AMERICA
Fig 4: Screen Display - PODS-F Initialization Completed (2 Of 2)
G12125510Courtesy of HYUNDAI MOTOR AMERICA
CAUTION: Erase the SRSCM diagnostic codes after completing the PODS-F zeroing.
NOTE: In case of zeroing failure
  • Code 01: Requestor ID out of range.
  • Code 02: ECU faults.
  • Code 03: ODS sensor short to ground.
  • Code 04: Open between ODS ECU and mat.
  • Code 05: ODS ECU has not been trimmed.
  • Code 06: Configuration disabled in ECU calibration.
  • Code 07: Configuration value out of range.
  • Code 08: Used in zero Request response only.
  • Code 09: Algo enabled this ignition cycles.
  • Code 0A: Upper offset value created during the zero process.
  • Code 0B: Lower offset value created during the zero process.
  • Code 0C: Voltage diagnostic
  • Code 0D: The delta of QX_Freq_Low and QX_Freq_High must remain low.
  • Code 0E: Temperature is above O deg C during the zero process.
  • Code 0F: Re-read QX Final compare delta limit. (zero verify)