Repair Procedures: Installation
NOTE:
Before installing, check that the Shift Lever in the "N" position.
- Install the Shift Lever Assembly (A).
Tightening Torque:
9.8 ~ 13.7 N.m (1.0 ~ 1.4 kgf.m, 7.2 ~ 10.1 lb-ft)
- Install the Shift Cable (A).NOTE: Insert the Shift Cable after checking the direction of Projection (B) to prevent wrong assembly.
- Connect the Main Connector (A).
- Install the Floor Console Assembly.
(Refer to: Body - "FLOOR CONSOLE ").
- Install the Shift Lever Knob Assembly.
- Install the Knob Assembly (A) and then fix the Pin (B).
- Install the Cover (A).
CAUTION: Check that operating surely at each range of the Inhibitor Switch corresponding to each position of the Shift Lever.