Connector Inspection Procedure
- Handling of Connector
- Never pull on the Wiring Harness when disconnecting Connectors.
- When removing the Connector with a lock, press or pull locking lever.
- Listen for a click when locking Connectors. This sound indicates that they are securely locked.
- When a Tester is used to check for Continuity, or to measure Voltage, always insert tester probe from wire harness side.
- Check Waterproof Connector Terminals from the Connector Side. Waterproof Connectors cannot be accessed from harness side.
NOTE:
- Use a fine Wire to prevent damage to the Terminal.
- DO NOT damage the Terminal when inserting the Tester Lead.
- Checking Point for Connector
- While the Connector is connected:
Hold the Connector, check connecting condition and locking efficiency.
- When the Connector is disconnected:
Check missed Terminal, crimped Terminal or broken core wire by slightly pulling the Wire Harness.
Visually check for rust, contamination, deformation and bend.
- Check Terminal Tightening Condition:
Insert a spare male Terminal into a Female Terminal and then check Terminal Tightening Conditions.
- Pull lightly on Individual Wires to ensure that each Wire is secured in the Terminal.
- While the Connector is connected:
- Repair Method of Connector Terminal
- Clean the contact points using air gun and/or shop rag.NOTE: NEVER use sand paper when polishing the contact points, otherwise the contact point may be damaged.
- In case of abnormal contact pressure, replace the Female Terminal.
- Clean the contact points using air gun and/or shop rag.