Description and Operation: Operation
WARNING: This page is about a different car, the 2013 Hyundai Veloster. However, it is still accessible from the selected car via links, so may be relevant.
OPERATING MOD DESCRIPTION
| OFF mod |
- Entry - LF command
- Air pressure sample: 60 sec
- Temperature sample: 60 sec
- Exit - LF command or pressure change of > 19 psi
|
| Stationary mod |
- Entry - From OFF mod or when no motion detected
- Air pressure sample: 60 sec
- Temperature sample: 60 sec
- Motion sample: 15 sec
- Exit - When detected motion by sensor & verified
|
| AL (Auto learning) mod |
- Entry - Motion detected
- Air pressure sample: 10.8 sec
- Temperature sample: 10.8 sec
- Motion sample: 10.8 sec
- Exit - Transmission of 16 blocks
|
| Roll mod |
- Entry - AL mod expires
- Air pressure sample: 15 sec
- Temperature sample: 15 sec
- Motion sample: 60 sec
- Exit - no further motion detected
|
| Service mod |
- Entry - Speed below detection level
- Air pressure sample: 15 sec
- Temperature sample: 15 sec
- Motion sample: 15 sec
- Exit - Further motion detected
|
| RF test mod |
- Entry - LF command
- Air pressure sample: 15 sec
- Temperature sample: 15 sec
- Motion sample: 15 sec
- Exit - Following 8 hrs duration
|
| Alter mod |
- Entry - Detection of pressure change
- Air pressure sample: 2 sec
- Temperature sample: 2 sec
- Exit - Following 2 pressure sample or pressure
|