Diagnosis Of Immobilizer Faults: Notes
- Communication between the ECM and the SMARTRA.
- Function of the SMARTRA and the transponder.
- Data (stored in the ECM related to the immobilizer function.
The following table shows the assignment of immobilizer related faults to each type:
DIAGNOSTIC TROUBLE CODE CHART
| Immobilizer Related Faults | Fault types | Diagnostic codes |
|---|---|---|
| PCM (ECM) fault | 1. Non-Immobilizer-EMS connected to an Immobilizer | P1610 |
| Transponder key fault |
|
P1674 (Transponder status error) |
| Transponder key fault | 1. Transponder programming error | P1675 (Transponder programming error) |
| SMARTRA fault | 1. Invalid message from SMARTRA to PCM (ECM) | P1676 (SMARTRA message error) |
| SMARTRA fault |
|
P1690 (SMARTRA no response) |
| Antenna coil fault | 1. Antenna coil open/short circuit | P1691 (Antenna coil error) |
| Immobilizer indicator lamp fault | 1. Immobilizer indicator lamp error (Cluster) | P1692 (Immobilizer lamp error) |
| Transponder key fault |
|
P1693 (Transponder no response error/invalid response) |
| PCM (ECM) fault | 1. Request from PCM (ECM) is invalid (Protocol layer violation-Invalid request, check sum error etc.) | P1694 (PCM (ECM) message error) |
| PCM (ECM) internal permanent memory (EEPROM) fault |
|
P1695 (PCM (ECM) memory error) |
| Invalid key fault | 1. Virgin transponder at PCM (ECM) status "Learnt" Learnt (Invalid) Transponder at PCM (ECM) status "Learnt" (Authentication fail) | P1696 (Authentication fail) |
| Hi-Scan fault | 1. Hi-Scan message error | P1697 |
| Locked by timer | 1. Exceeding the maximum limit of Twice IGN ON (2 32 times) | P1699 (Twice IG ON over trial) |