DTC P0125 Insufficient Coolant Temperature For Closed Loop Fuel Control: DTC Detecting Condition
DTC DETECTING CONDITION CHART
| Item |
Detecting Condition |
Possible cause |
| DTC Strategy |
- This diagnostic monitors the time it takes for the coolant temperature to reach the closed loop temperature and compares against a maximum threshold in order to make a PASS/FAIL determination, provided airflow and idle conditions are met.
|
- Poor connection
- Improper coolant level
- Malfunctioning Cooling System
- Faulty ECTS
|
| Enable Conditions |
- No disabling faults present
- Coolant sensor within range
- Startup coolant temp ≤ 34°C (86 °F)
- Engine running
|
| Threshold value |
- Undefaulted coolant temperature ≥ Threshold Value (°C)
- Test Time = Threshold (second)
|
| Diagnosis Time |
- More than 5 second failure.
|
| MIL On Condition |
|