Ground Circuit Inspection
- IG "OFF"
- Disconnect FLS & Instrument cluster connector.
- Measure resistance between terminal 6 of FLS harness connector and chassis ground.
Specification : Approx. below 1Ω
- Is the measured resistance within specification ?
YES
- Go to "COMPONENT CIRCUIT INSPECTION " procedure.
NO
- Repair or replace as necessary and go to "VERIFICATION OF VEHICLE REPAIR " procedure.