Control Circuit Inspection
- Key "OFF".
- Disconnect fuel pump relay.
- Key "ON".
- Measure the voltage between terminal 5 of fuel pump relay harness connector and chassis ground.
Specification: Approx. 3.5V
- Is the measured voltage within specifications?
YES : --> Go to "COMPONENT INSPECTION " procedure.
NO : --> Repair Open in control circuit, and go to "VERIFICATION OF VEHICLE REPAIR " procedure.