Service Point
If a new compressor is installed, first adjust the amount of oil according to the procedures described below, and then install the compressor.
- Measure the amount (X cm3 ) of oil inside the removed compressor.
- Drain the amount of oil calculated according to the following formula from the new compressor, and then install the new compressor. New compressor oil amount: 150 cm3 - X cm3 = Y cm3
NOTE:
- Y cm3 indicates the amount of oil in the refrigerant line, the condenser, the cooling unit, etc.
- When replacing the following parts at the same time as the compressor, subtract the rated oil amount of each part from Y cm3 and discharge this amount from the new compressor.
Compressor oil: FD46XG (PAG OIL)
Quantity:
Evaporator: 30 cm3 (1.0 fl.oz.)
Condenser: 40 cm3 (1.4 fl.oz.)
Suction hose: 10 cm3 (0.3 fl.oz.)
Receiver: 20 cm3 (0.6 fl.oz.)