Mike's Workshop Manuals: Service manuals for every vehicle
Home >> Hyundai >> 2004 >> Elantra GLS, Standard >> Repair and Diagnosis >> Engine Performance >> Engine Control Systems >> Fuel System >> DTC Trouble Shooting Procedures >> DTC P0076: Intake Valve Control Solenoid Circuit Low - Oil-Flow Control Valve (OCV) >> Inspection Procedures >> 4. Check For Short To Ground In Harness

4. Check For Short To Ground In Harness

  1. Keep the ECM and OCV connectors disconnected.
  2. Measure resistance between terminal 2 of the OCV harness connector and chassis ground.
    Fig 1: Checking OCV Harness For Short To Ground
    G00748499Courtesy of HYUNDAI MOTOR CO.

Does resistance indicate open? 

Yes: Proceed with ECM problem procedure.

No: Repair short to chassis ground in harness.