5. Check For Short To Ground In Harness
- Disconnect ECM connector.
- Measure resistance between terminal 6 of the HO2S harness connector and chassis ground.
- Specification : infinite
Does resistance indicate open?
Yes: Proceed with ECM problem procedure.
No: Repair short to chassis ground in harness.