Installation Procedure
- Install a new O-ring seal to the actuator solenoid valve (2).
- Lightly lubricate the O-ring seal with clean engine oil.
- Install the CMP actuator solenoid valve (2) into the cylinder head.
- Install the camshaft position actuator solenoid valve bolt (3).
Tighten: Tighten the bolt to 10 N.m (89 lb in).
- Connect the engine wiring harness electrical connector (1) to the CMP actuator solenoid valve (6).
CAUTION:
Refer to Fastener Caution
.
Fig 2: View Of CMP Sensor Connector, Exhaust Camshaft Actuator Connector & Engine Wiring Harness Retainer