Installation Procedure
- Handle the MAF sensor carefully.
- Do not drop the MAF sensor in order to prevent damage to the MAF sensor.
- Do not damage the screen located on the air inlet end of the MAF.
- Do not touch the sensing elements.
- Do not allow solvents and lubricants to come in contact with the sensing elements.
- Use a small amount of a soap based solution in order to aid in the installation.
- Insert the MAF/IAT sensor into the air cleaner assembly.
- Install the screws securing the MAF/IAT sensor to the air cleaner assembly.
Tighten: Tighten the screws to 2.25 N.m (20 lb in).
- Connect the electrical connector to the MAF/IAT sensor.
NOTE:
NOTE:
Refer to Fastener Notice
in Cautions and Notices.