Conditions for Running
- At least 17 hours have elapsed since the last drive cycle met the Conditions for Running.
- The difference between the startup engine coolant temperature (ECT) and the startup intake air temperature (IAT) is less than 8°C (14.4°F).
- The barometric pressure (BARO) is more than 74 kPa.
- The startup ECT is between 4-30°C (39-86°F).
- The startup IAT is between 4-30°C (39-86°F).
- The fuel level is between 15-85 percent.
- The battery voltage is between 10-18 volts.
- The fuel level does not increase more than 9 percent during this drive cycle.
- The engine run time is at least 10 minutes.
- The vehicle has been driven at least 5 km (3.15 miles) this drive cycle.
- The estimated ambient temperature at the end of this drive cycle is between 2-32°C (36-89°F).
- The shutdown ECT is at least 70°C (158°F).
- The ignition is turned OFF for at least 1 hour after this drive cycle.