Enable Conditions
| Condition | Minimum | Maximum | |
|---|---|---|---|
| Engine speed [Engine Speed] | 500 rpm | - | |
| 12 volt battery voltage [Battery Voltage] | 10 V | - | |
| Other | Clutch pressure control solenoid valve A actual current value is 400 mA or more, or shift solenoid valve D is ON condition | ||
| Not while switching to two-way clutch | |||
| Engine speed, 12 volt battery voltage, and other conditions in Enable Conditions should be satisfied continuous for at least 1.5 seconds | |||
[ ]: HDS Parameter