Mike's Workshop Manuals: Service manuals for every vehicle
Home >> Honda >> 2023 >> Pilot EX-L, AWD >> Repair and Diagnosis >> Engine Performance >> System >> Engine Control System - Advanced Diagnostics (P0571 - U129E) >> Advanced Diagnostics >> DTC Advanced Diagnostics: P16BB >> Enable Conditions

Enable Conditions

Condition Minimum Maximum
Engine speed [Engine Speed] 500 rpm 3, 000 rpm
Alternator control voltage 14.5 V -
Alternator power generation amount 1 % 50 %
Other LIN communication is OK

[ ]: HDS Parameter