Inspection Procedure
- 1. Valve - Remove
- 2. Valve - Inspect
- 3. Valve Stem-to-Guide Clearance - Inspect
1. Subtract the O.D. of the valve stem, measured with a micrometer, from the I.D. of the valve guide, measured with an inside micrometer or ball gauge. Take the measurements in three places along the valve stem and three places inside the valve guide. The difference between the largest valve guide measurement and the smallest valve stem measurement should not exceed the service limit.