DTC Troubleshooting Index
CHECKING DTCS WITH HDS
| DTC | Detection Item or Symptom | ECU | DTC type |
|---|---|---|---|
| DTC U1280 | Communication bus line error (BUS-OFF) | HVAC control unit | Loss of communication |
| U128D | Lost Communication with Gauge Control Module (HVAC Control Unit) | HVAC control unit | Loss of communication |
| B1215 | An open or short in the recirculation control motor circuit | HVAC control unit | Signal error |
| B1223 | A problem in the rear blower motor circuit | HVAC control unit | Signal error |
| B1227 | An open in the outside air temperature sensor circuit | HVAC control unit | Signal error |
| B1228 | A short in the outside air temperature sensor circuit | HVAC control unit | Signal error |
| B1231 | An open in the evaporator temperature sensor circuit | HVAC control unit | Signal error |
| B1232 | A short in the evaporator temperature sensor circuit | HVAC control unit | Signal error |
| B1233 | An open in the air mix control motor circuit (front) | HVAC control unit | Signal error |
| B1234 | A short in the air mix control motor circuit (front) | HVAC control unit | Signal error |
| B1235 | A problem in the air mix control motor circuit, linkage, door, or motor (front) | HVAC control unit | Signal error |
| B1239 | An open or short in the mode control motor circuit (front) | HVAC control unit | Signal error |
| B1240 | A problem in the mode control motor circuit, linkage, door, or motor (front) | HVAC control unit | Signal error |
| B1241 | A problem in the blower motor circuit (front) | HVAC control unit | Signal error |
| B1244 | An open in the rear air mix control motor circuit | HVAC control unit | Signal error |
| B1245 | A short in the rear air mix control motor circuit | HVAC control unit | Signal error |
| B1246 | A problem in the rear air mix control motor circuit, linkage, door, or motor | HVAC control unit | Signal error |
| B2965 | Rear communication failure | HVAC control unit | Loss of communication |
| B2979 | An open in the A/C pressure sensor circuit | HVAC control unit | Signal error |
| B2980 | A short in the A/C pressure sensor circuit | HVAC control unit | Signal error |
| B2983 | A problem in the recirculation control motor circuit, linkage, door, or motor | HVAC control unit | Signal error |