Air Mix Control Motor Test
NOTE:
Before testing, check for HVAC DTCs (see
GENERAL TROUBLESHOOTING INFORMATION ).
- Disconnect the 7P connector from the air mix control motor.NOTE: Incorrectly applying power and ground to the air mix control motor will damage it. Follow the instructions carefully.
- Connect battery power to terminal No. 1 of the air mix control motor, and ground terminal No. 2; the air mix control motor should run, and stop at Max Cool. If it doesn't, reverse the connections; the air mix control motor should run, and stop at Max Hot. When the air mix control motor stops running, disconnect battery power immediately.
- If the air mix control motor did not run in step 2, remove it, then check the air mix control linkage and door for smooth movement.
- If the linkage and door move smoothly, replace the air mix control motor (see AIR MIX CONTROL MOTOR TEST ).
- If the linkage or door sticks or binds, repair them as needed.
- If the air mix control motor runs smoothly, Go to step 4.
- Measure the resistance between terminal No. 5 and No. 7 of the air mix control motor. It should be between 4.2 and 7.8 kΩ.
- Reconnect the air mix control motor 7P connector, then turn the ignition switch ON (II).
- Using the backprobe set, measure the voltage between terminals No. 3 and No. 5.
Max Cool: About 0.5 V
Max Hot: About 4.5 V
- If either the resistance or the voltage readings are not as specified, replace the air mix control motor (see AIR MIX CONTROL MOTOR TEST ).