DTC 81-12: VSA Modulator-Control Unit Internal Circuit Malfunction
- Turn the ignition switch to ON (II).
- Clear the DTC with the HDS.
- Turn the ignition switch to LOCK (0) and then back to ON (II).
- Check for DTCs with the HDS.
Is DTC 81-12 indicated?
YES -Go to next step.
NO -Intermittent failure, the system is OK at this time. Refer to Intermittent Failures ).
- Turn the ignition switch to LOCK (0).
- Disconnect the steering angle sensor 5P connector (see STEERING ANGLE SENSOR REPLACEMENT ).
- Disconnect the VSA modulator-control unit 22P connector (see step 4 on ).
- Turn the ignition switch to ON (II).
- Measure the voltage between steering angle sensor 5P connector terminal No. 1 and body ground.
Courtesy of AMERICAN HONDA MOTOR CO., INC.
Is there 0.1 V or more?
YES -Repair a short to power in the wire between the steering angle sensor and the VSA modulator-control unit.
NO -Go to next step.
- Turn the ignition switch to LOCK (0).
- Reconnect all connectors.
- Update the VSA modulator-control unit if it does not have the latest software (see VSA MODULATOR-CONTROL UNIT UPDATE ). If the unit already has the latest software, substitute a known-good VSA modulator-control unit (see VSA MODULATOR-CONTROL UNIT REMOVAL AND INSTALLATION ).
- Turn the ignition switch to LOCK (0) and then back to ON (II).
- Check for DTCs with the HDS.
Is DTC 81-12 indicated?
YES -Check for loose terminals in the VSA modulator-control unit 22P connector. If the VSA modulator-control unit was updated, substitute a known-good VSA modulator-control unit (see VSA MODULATOR-CONTROL UNIT REMOVAL AND INSTALLATION ), then retest. If the VSA modulator-control unit was substituted, go to 1.
NO -If the VSA modulator-control unit was updated, troubleshooting is complete. If the VSA modulator-control unit was substituted, replace the original VSA modulator-control unit (see VSA MODULATOR-CONTROL UNIT REMOVAL AND INSTALLATION ). If any other DTCs are indicated, go to the indicated DTCs troubleshooting.