Mike's Workshop Manuals: Service manuals for every vehicle
Home >> Honda >> 1993 >> Prelude VTEC >> Repair and Diagnosis >> Engine Performance >> System >> Engine Controls - System/Component Tests >> Emission Systems & Sub-Systems >> Fuel Evaporation >> EVAP Purge Control Solenoid Valve

EVAP Purge Control Solenoid Valve

  1. Disconnect vacuum hose from EVAP purge control diaphragm valve, located on charcoal canister. Connect vacuum gauge to hose. Start and idle engine. Engine coolant temperature must be below 167°F (75°C) on all engines except D15Z1. On D15Z1, temperature must be below 158°F (70°C).
  2. If vacuum does not exist, go to step 4). If vacuum exists, unplug connector at EVAP purge control solenoid valve. See EVAP PURGE CONTROL SOLENOID LOCATION  table. Measure voltage between specified wires. See EVAP PURGE CONTROL SOLENOID CONNECTOR IDENTIFICATION  table.
    EVAP PURGE CONTROL SOLENOID LOCATION

    Application Location
    Accord In Control Box On Firewall
    Civic & Civic Del Sol Left Of IAC Valve
    Prelude Near Throttle Position Sensor
    EVAP PURGE CONTROL SOLENOID CONNECTOR IDENTIFICATION

    Application Positive Terminal Wire Color Negative Terminal Wire Color
    Accord & Prelude
    (4-Pin Connector) Black/Yellow Red/Green
    Civic & Civic Del Sol
    (2-Pin Connector) Yellow/Black Red
  3. If battery voltage exists, inspect vacuum hose for leaks, blockage and incorrect routing. If hose is okay, replace EVAP purge control solenoid valve. If voltage does not exist, measure voltage between positive terminal and chassis ground. If battery voltage does not exist, repair open circuit in appropriate positive wire. If voltage exists, check for open circuit between negative terminal and ECM. If wire is okay, replace ECM.
  4. Warm engine to full operating temperature (cooling fan comes on). Turn off and restart engine. If vacuum now exists, go to CHARCOAL CANISTER  . If vacuum does not exist, unplug connector at EVAP purge control solenoid valve.
  5. If vacuum now exists, check for short circuit in negative wire between harness connector and ECM. If wire is okay, substitute known good ECM. Retest system. If system now operates properly, replace ECM. If vacuum still does not exist, check vacuum hose for leaks, blockage and improper routing. If hose is okay, replace EVAP purge control solenoid valve.