Draining & Refilling
CAUTION:
Manufacturer recommends flushing oil cooler whenever transmission or transaxle is removed.
- Remove drain plug from bottom of transaxle oil pan and drain fluid. Remove 15 oil pan bolts, oil pan, oil pan guard, gasket and filter screen. Note position of 2 cross-grooved oil pan bolts. See Fig 1. If oil pan is frozen to transaxle case, use a rubber mallet and a wood block to remove it. DO NOT pry oil pan away from transfer case.
- Install clean filter screen and NEW gasket. Tighten retaining bolts to 53 INCH lbs. (6 N.m). Install oil pan and NEW gasket. Apply thread sealant to threads of 2 cross-grooved bolts. DO NOT apply thread sealant to other 13 bolts. Tighten oil pan bolts to 53 INCH lbs. (6 N.m). Tighten drain plug to 17 ft. lbs. (23 N.m).
- Add 1.6 qts. (1.5L) of Dexron-III through dipstick tube. Check fluid level. See CHECKING FLUID LEVEL .