Code 3, Open Dump Solenoid Circuit
- Turn ignition off. Disconnect RWAL EBCM connector. Measure resistance between RWAL EBCM terminal No. 9 and ground. See Figure .
- If resistance reading is 1-3 ohms, check RWAL EBCM connections. If connections are okay, replace RWAL EBCM.
- If resistance reading is greater than 3 ohms, disconnect pressure limit valve. Measure resistance between limit valve terminal No. 3 and ground terminal No. 4. See Figure .
- If resistance is now 1-3 ohms, repair open in harness White/Green or Black wire. If resistance is greater than 3 ohms, dump solenoid winding is open. Replace pressure limit valve.