DTC Description
P0A1B00 is set when an internal communication failure is detected in the MCU*.
WARNING:
To prevent electricity-related accidents, follow the instructions below to cut the high voltage off.
- IG OFF.
- Remove the (-) cable of the auxiliary battery.
- Wear insulated gloves, safety glasses and use insulated tools for your safety.
- Remove service plug, wait for more than 5 minutes so for discharging the inverter capacitor.
- Check the inverter capacitor discharge: Voltage between the inverter terminals should be below 30V.