Control Relay Power Circuit Inspection
- Ignition switch OFF and disconnect main relay (Metal core block) and ECM connector.
- Measure the resistance between control relay power terminal of main relay (Metal core block) harness connector and main relay control relay power terminal of ECM harness connector.
Specification: Approx. below 1Ω
- Is the measured resistance within specification?
YES
- Go to "COMPONENT INSPECTION ".
NO
- Repair or replace as necessary and then, go to "VERIFICATION OF VEHICLE REPAIR "