Mike's Workshop Manuals: Service manuals for every vehicle
Home >> Genesis >> 2021 >> G80 2.5T Advanced, AWD >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> Heater System >> Console Mode Actuator >> Specifications

Console Mode Actuator: Specifications

* Voltage output value dependent on console mode actuator position.

Door Position Voltage (4-5) Error Detecting
VENT 0.55 ± 0.15V Low Voltage: 0.1V less
FLOOR 4.45 ± 0.15V High Voltage: 4.9V more