Console Mode Actuator: Specifications
* Voltage output value dependent on console mode actuator position.
Door Position
Voltage (4-5)
Error Detecting
VENT
0.55 ± 0.15V
Low Voltage: 0.1V less
FLOOR
4.45 ± 0.15V
High Voltage: 4.9V more