Repair Procedures: Inspection

  1. Check the resistance of the ambient temperature sensor between terminals 1 and 2 whether it changes by changing the ambient temperature.
    G15555053Courtesy of HYUNDAI MOTOR AMERICA

    Specification 

    Ambient temperature [°C (°F)] Resistance between terminal 1 and 2 (kΩ ± 3%)
    -30 (-22) 480.41
    -20 (-4) 271.21
    -10 (14) 158.1
    0 (32) 95.096
    10 (50) 58.799
    20 (68) 37.315
    30 (86) 24.26
    40 (104) 16.13
    50 (122) 10.95