Typical Scan Tool Data
Ignition 1 Signal
| Circuit | Short to Ground | Open | Short to Voltage |
|---|---|---|---|
| Operating Conditions: Ignition ON, engine OFF, and ignition main and engine control module relays are commanded ON | |||
| Ignition 1 Signal, Ignition Main Relay | 0 V | 0 V | B+ |
| Engine Controls Ignition Relay Feedback Signal, Engine Control Module Relay | 0 V | 0 V | B+ |