Installation Procedure
- Connect the wires to the solenoid.
Tighten:
- Tighten the battery positive cable nut to 9 N.m (80 lb in).
- Tighten the engine wiring harness to starter nut to 1.9 N.m (17 lb in).
- Install the starter and the inboard starter mounting bolt. Do not tighten.
- Install the starter shims, if equipped.
- Install the outboard starter mounting bolt.
Tighten: Tighten the starter mounting bolts to 50 N.m (37 lb ft).
- Install the differential carrier shield, if equipped.
- Install the differential carrier shield mounting bolts, if equipped.
Tighten: Tighten the differential carrier bolts to 25 N.m (18 lb ft).
- Lower the vehicle.
- Connect the battery negative cable. Refer to Battery Negative Cable Disconnect/Connect Procedure .
NOTE:
Refer to Fastener Notice in Cautions and Notices.