Installation Procedure
- Install the striker and shim(s) to the roof panel.
- Install the bolts retaining the striker to the roof panel.
- Adjust the striker using the procedure below:
- Tighten the bolts to a sung fit.
- Close the door to self align striker.
- Check for door fit.
- Add or remove shims as required (maximum of 3).
Tighten: Tighten the striker bolts to 10 N.m (89 lb in).
- Install the upper latch striker cover.
NOTE:
Refer to Fastener Notice
in Cautions and Notices.