| B11EE:19 |
A/C Compressor: Circuit Current Above Threshold |
GO to Pinpoint Test R |
| B11EE:41 |
A/C Compressor: General Checksum Failure |
GO to Pinpoint Test AE |
| B11EE:4B |
A/C Compressor: Over Temperature |
GO to Pinpoint Test R |
| B11EE:92 |
A/C Compressor: Performance Or Incorrect Operation |
GO to Pinpoint Test R |
| P0562:00 |
System Voltage Low: No Sub Type Information |
GO to Pinpoint Test R |
| P0563:00 |
System Voltage High: No Sub Type Information |
GO to Pinpoint Test R |
| P0AFA:16 |
Hybrid/EV Battery System Voltage Low: Circuit Voltage Below Threshold |
GO to Pinpoint Test R |
| P0AFB:17 |
Hybrid/EV Battery System Voltage High: Circuit Voltage Above Threshold |
GO to Pinpoint Test R |
| P0AFB:1C |
Hybrid/EV Battery System Voltage High: Circuit Voltage Out Of Range |
GO to Pinpoint Test R |
| U0001:88 |
High Speed CAN Communication Bus: Bus Off |
GO to Pinpoint Test T |
| U0100:00 |
Lost Communication With ECM/PCM 'A': No Sub Type Information |
GO to Pinpoint Test U |
| U0111:00 |
Lost Communication With Battery Energy Control Module 'A': No Sub Type Information |
GO to Pinpoint Test V |
| U0140:00 |
Lost Communication With Body Control Module: No Sub Type Information |
GO to Pinpoint Test W |
| U3000:04 |
Control Module: System Internal Failure |
GO to Pinpoint Test AE |
| U3000:42 |
Control Module: General Memory Failure |
GO to Pinpoint Test AE |
| U3000:49 |
Control Module: Internal Electronic Failure |
GO to Pinpoint Test AE |
| P2611:00 |
A/C Refrigerant Distribution Valve 'A' Control Circuit/Open: No Sub Type Information |
GO to Pinpoint Test S
. |
| P2612:00 |
A/C Refrigerant Distribution Valve 'A' Control Circuit Low: No Sub Type Information |
GO to Pinpoint Test S |
| P2613:00 |
A/C Refrigerant Distribution Valve 'A' Control Circuit High: No Sub Type Information |
GO to Pinpoint Test S |
| B1663:11 |
Vapor Injection Heat Pump Outside Heat Exchanger Outlet Temperature Sensor: Circuit Short To Ground |
GO to Pinpoint Test AS |
| B1663:15 |
Vapor Injection Heat Pump Outside Heat Exchanger Outlet Temperature Sensor: Circuit Short To Battery Or Open |
GO to Pinpoint Test AS |
| B1664:12 |
Vapor Injection Heat Pump Low Side Refrigerant Shut Off Solenoid: Circuit Short To Battery |
GO to Pinpoint Test AT |
| B1664:14 |
Vapor Injection Heat Pump Low Side Refrigerant Shut Off Solenoid: Circuit Short To Ground Or Open |
GO to Pinpoint Test AT |
| B1665:12 |
Vapor Injection Heat Pump Cooling Electronic Expansion Valve: Circuit Short To Battery |
GO to Pinpoint Test AP |
| B1665:14 |
Vapor Injection Heat Pump Cooling Electronic Expansion Valve: Circuit Short To Ground Or Open |
GO to Pinpoint Test AP |
| B1665:71 |
Vapor Injection Heat Pump Cooling Electronic Expansion Valve: Actuator Stuck |
GO to Pinpoint Test AP |
| B1665:74 |
Vapor Injection Heat Pump Cooling Electronic Expansion Valve: Actuator Slipping |
GO to Pinpoint Test AP |
| B1665:93 |
Vapor Injection Heat Pump Cooling Electronic Expansion Valve: No Operation |
GO to Pinpoint Test AP |
| B1666:12 |
Vapor Injection Heat Pump Cooling Liquid Gas Separator Valve: Circuit Short To Battery |
GO to Pinpoint Test AU |
| B1666:14 |
Vapor Injection Heat Pump Cooling Liquid Gas Separator Valve: Circuit Short To Ground Or Open |
GO to Pinpoint Test AU |
| B168B:14 |
Second Row Legrest Backward Switch: Circuit Short To Ground Or Open |
GO to Pinpoint Test AV |
| B168E:12 |
Vapor Injection Heat Pump Heating Liquid Gas Separator Valve: Circuit Short To Battery |
GO to Pinpoint Test AV |
| B168F:12 |
Vapor Injection Heat Pump Battery Chiller Electronic Expansion Valve: Circuit Short To Battery |
GO to Pinpoint Test AQ |
| B168F:14 |
Vapor Injection Heat Pump Battery Chiller Electronic Expansion Valve: Circuit Short To Ground Or Open |
GO to Pinpoint Test AQ |
| B168F:71 |
Vapor Injection Heat Pump Battery Chiller Electronic Expansion Valve: Actuator Stuck |
GO to Pinpoint Test AQ |
| B168F:74 |
Vapor Injection Heat Pump Battery Chiller Electronic Expansion Valve: Actuator Slipping |
GO to Pinpoint Test AQ |
| B168F:93 |
Vapor Injection Heat Pump Battery Chiller Electronic Expansion Valve: No Operation |
GO to Pinpoint Test AQ |
| B169D:12 |
Vapor Injection Heat Pump Heating Electronic Expansion Valve: Circuit Short To Battery |
GO to Pinpoint Test AR |
| B169D:14 |
Vapor Injection Heat Pump Heating Electronic Expansion Valve: Circuit Short To Ground Or Open |
GO to Pinpoint Test AR |
| B169D:71 |
Vapor Injection Heat Pump Heating Electronic Expansion Valve: Actuator Stuck |
GO to Pinpoint Test AR |
| B169D:74 |
Vapor Injection Heat Pump Heating Electronic Expansion Valve: Actuator Slipping |
GO to Pinpoint Test AR |
| B169D:93 |
Vapor Injection Heat Pump Heating Electronic Expansion Valve: No Operation |
GO to Pinpoint Test AR |
| B169E:11 |
Vapor Injection Heat Pump Compressor Outlet Temperature Sensor: Circuit Short To Ground |
GO to Pinpoint Test AS |
| B169E:15 |
Vapor Injection Heat Pump Compressor Outlet Temperature Sensor: Circuit Short To Battery Or Open |
GO to Pinpoint Test AS |
| B169F:11 |
Vapor Injection Heat Pump Evaporator Outlet Temperature Sensor: Circuit Short To Ground |
GO to Pinpoint Test AS |
| B169F:15 |
Vapor Injection Heat Pump Evaporator Outlet Temperature Sensor: Circuit Short To Battery Or Open |
GO to Pinpoint Test AS |
| B1717:06 |
Vapor Injection Heat Pump: Algorithm Based Failure |
GO to Pinpoint Test AW |
| B1717:7A |
Vapor Injection Heat Pump: Fluid Leak Or Seal Failure |
GO to Pinpoint Test AW |
| U0100:00 |
Lost Communication With ECM/PCM 'A': No Sub Type Information |
GO to Pinpoint Test U |
| U0140:00 |
Lost Communication With Body Control Module: No Sub Type Information |
GO to Pinpoint Test W |
| U0164:00 |
Lost Communication With HVAC Control Module 'A': No Sub Type Information |
GO to Pinpoint Test Z |
| U016B:00 |
Lost Communication With A/C Compressor 'A' Control Module: No Sub Type Information |
GO to Pinpoint Test AM |
| U019B:00 |
Lost Communication With Battery Charger Control Module 'A': No Sub Type Information |
GO to Pinpoint Test AN |
| U0293:00 |
Lost Communication With Hybrid/EV Powertrain Control Module 'A': No Sub Type Information |
GO to Pinpoint Test U |
| U0401:68 |
Invalid Data Received from ECM/PCM A: Event Information |
GO to Pinpoint Test AB |
| U0401:81 |
Invalid Data Received from ECM/PCM A: Invalid Serial Data Received |
GO to Pinpoint Test AB |
| U040A:68 |
Invalid Data Received From Air Conditioning Control Module: Event Information |
GO to Pinpoint Test AB |
| U0422:68 |
Invalid Data Received From Body Control Module: Event Information |
GO to Pinpoint Test AB |
| U0422:81 |
Invalid Data Received From Body Control Module: Invalid Serial Data Received |
GO to Pinpoint Test AB
= |
| U0424:68 |
Invalid Data Received from HVAC Control Module 'A': Event Information |
GO to Pinpoint Test AB |
| U0424:81 |
Invalid Data Received from HVAC Control Module 'A': Invalid Serial Data Received |
GO to Pinpoint Test AB |
| U049C:68 |
Invalid Data Received From Battery Charger Control Module 'A': Event Information |
GO to Pinpoint Test AB |
| U049C:81 |
Invalid Data Received From Battery Charger Control Module 'A': Invalid Serial Data Received |
GO to Pinpoint Test AB |
| U0594:68 |
Invalid Data Received From Hybrid/EV Powertrain Control Module 'A': Event Information |
GO to Pinpoint Test AB |
| U0594:81 |
Invalid Data Received From Hybrid/EV Powertrain Control Module 'A': Invalid Serial Data Received |
GO to Pinpoint Test AB |
| U1000:00 |
Solid State Driver Protection Active -Driver Disabled: No Sub Type Information |
GO to Pinpoint Test AC |
| U2024:51 |
Control Module Cal-Config Data: Not Programmed |
GO to Pinpoint Test AD |
| U2100:00 |
Initial Configuration Not Complete: No Sub Type Information |
GO to Pinpoint Test AD |
| U3000:41 |
Control Module: General Checksum Failure |
GO to Pinpoint Test AE |
| U3000:49 |
Control Module: Internal Electronic Failure |
GO to Pinpoint Test AE |
| U3002:62 |
Vehicle Identification Number: Signal Compare Failure |
GO to Pinpoint Test AO
. |
| U3003:16 |
Battery Voltage: Circuit Voltage Below Threshold |
GO to Pinpoint Test AF |
| U3003:17 |
Battery Voltage: Circuit Voltage Above Threshold |
GO to Pinpoint Test AG |
| B1081:07 |
Left Temperature Damper Motor: Mechanical Failure |
GO to Pinpoint Test I |
| B1081:11 |
Left Temperature Damper Motor: Circuit Short To Ground |
GO to Pinpoint Test I |
| B1081:12 |
Left Temperature Damper Motor: Circuit Short To Battery |
GO to Pinpoint Test I |
| B1081:13 |
Left Temperature Damper Motor: Circuit Open |
GO to Pinpoint Test I |
| B1082:07 |
Right Temperature Damper Motor: Mechanical Failure |
GO to Pinpoint Test J |
| B1082:11 |
Right Temperature Damper Motor: Circuit Short To Ground |
GO to Pinpoint Test J |
| B1082:12 |
Right Temperature Damper Motor: Circuit Short To Battery |
GO to Pinpoint Test J |
| B1082:13 |
Right Temperature Damper Motor: Circuit Open |
GO to Pinpoint Test J |
| B1083:07 |
Recirculation Damper Motor: Mechanical Failure |
GO to Pinpoint Test A |
| B1083:11 |
Recirculation Damper Motor: Circuit Short To Ground |
GO to Pinpoint Test A |
| B1083:12 |
Recirculation Damper Motor: Circuit Short To Battery |
GO to Pinpoint Test A |
| B1083:13 |
Recirculation Damper Motor: Circuit Open |
GO to Pinpoint Test A |
| B1086:07 |
Air Distribution Damper Motor: Mechanical Failure |
GO to Pinpoint Test B |
| B1086:11 |
Air Distribution Damper Motor: Circuit Short To Ground |
GO to Pinpoint Test B |
| B1086:12 |
Air Distribution Damper Motor: Circuit Short To Battery |
GO to Pinpoint Test B |
| B1086:13 |
Air Distribution Damper Motor: Circuit Open |
GO to Pinpoint Test B |
| B10AF:11 |
Blower Fan Relay: Circuit Short To Ground |
GO to Pinpoint Test K |
| B10AF:12 |
Blower Fan Relay: Circuit Short To Battery |
GO to Pinpoint Test L |
| B10AF:13 |
Blower Fan Relay: Circuit Open |
GO to Pinpoint Test K
. |
| B10B3:11 |
Right Panel Air Discharge Temperature: Circuit Short To Ground |
GO to Pinpoint Test M |
| B10B3:15 |
Right Panel Air Discharge Temperature: Circuit Short To Battery Or Open |
GO to Pinpoint Test M |
| B10B4:11 |
Right Floor Air Discharge Temperature: Circuit Short To Ground |
GO to Pinpoint Test M |
| B10B4:15 |
Right Floor Air Discharge Temperature: Circuit Short To Battery Or Open |
GO to Pinpoint Test M |
| B10B5:11 |
Left Panel Air Discharge Temperature: Circuit Short To Ground |
GO to Pinpoint Test M |
| B10B5:15 |
Left Panel Air Discharge Temperature: Circuit Short To Battery Or Open |
GO to Pinpoint Test M |
| B10B6:11 |
Left Floor Air Discharge Temperature: Circuit Short To Ground |
GO to Pinpoint Test M |
| B10B6:15 |
Left Floor Air Discharge Temperature: Circuit Short To Battery Or Open |
GO to Pinpoint Test M |
| B10B9:12 |
Blower Control: Circuit Short To Battery |
GO to Pinpoint Test K |
| B10B9:14 |
Blower Control: Circuit Short To Ground Or Open |
GO to Pinpoint Test K |
| B10B9:14 |
Blower Control: Circuit Short To Ground Or Open |
GO to Pinpoint Test L |
| B11E5:11 |
Left HVAC Damper Position Sensor: Circuit Short To Ground |
GO to Pinpoint Test I |
| B11E5:15 |
Left HVAC Damper Position Sensor: Circuit Short To Battery Or Open |
GO to Pinpoint Test I |
| B11E6:11 |
Right HVAC Damper Position Sensor: Circuit Short To Ground |
GO to Pinpoint Test J |
| B11E6:15 |
Right HVAC Damper Position Sensor: Circuit Short To Battery Or Open |
GO to Pinpoint Test J |
| B11E7:11 |
Air Distribution Damper Position Sensor: Circuit Short To Ground |
GO to Pinpoint Test B |
| B11E7:15 |
Air Distribution Damper Position Sensor: Circuit Short To Battery Or Open |
GO to Pinpoint Test B |
| B11F0:11 |
Air Intake Damper Position Sensor: Circuit Short To Ground |
GO to Pinpoint Test A |
| B11F0:15 |
Air Intake Damper Position Sensor: Circuit Short To Battery Or Open |
GO to Pinpoint Test A |
| B162E:12 |
Max Defrost LED: Circuit Short To Battery |
GO to Pinpoint Test AK |
| B162E:14 |
Max Defrost LED: Circuit Short To Ground Or Open |
GO to Pinpoint Test AK |
| B164C:11 |
Passenger Floor Airflow Shutoff Position Sensor: Circuit Short To Ground |
GO to Pinpoint Test AL |
| B164C:15 |
Passenger Floor Airflow Shutoff Position Sensor: Circuit Short To Battery Or Open |
GO to Pinpoint Test AL |
| B164D:07 |
Passenger Floor Airflow Shutoff Motor: Mechanical Failure |
GO to Pinpoint Test AL |
| B164D:11 |
Passenger Floor Airflow Shutoff Motor: Circuit Short To Ground |
GO to Pinpoint Test AL |
| B164D:12 |
Passenger Floor Airflow Shutoff Motor: Circuit Short To Battery |
GO to Pinpoint Test AL |
| B164D:13 |
Passenger Floor Airflow Shutoff Motor: Circuit Open |
GO to Pinpoint Test AL |
| B1A61:11 |
Cabin Temperature Sensor: Circuit Short To Ground |
GO to Pinpoint Test N |
| B1A61:15 |
Cabin Temperature Sensor: Circuit Short To Battery Or Open |
GO to Pinpoint Test N |
| B1A63:11 |
Right Solar Sensor: Circuit Short To Ground |
GO to Pinpoint Test O |
| B1A63:15 |
Right Solar Sensor: Circuit Short To Battery Or Open |
GO to Pinpoint Test O |
| B1A64:11 |
Left Solar Sensor: Circuit Short To Ground |
GO to Pinpoint Test O |
| B1A64:15 |
Left Solar Sensor: Circuit Short To Battery Or Open |
GO to Pinpoint Test O |
| B1A69:11 |
Humidity Sensor: Circuit Short To Ground |
GO to Pinpoint Test N |
| B1A69:15 |
Humidity Sensor: Circuit Short To Battery Or Open |
GO to Pinpoint Test N |
| B1A69:92 |
Humidity Sensor: Performance Or Incorrect Operation |
GO to Pinpoint Test N |
| B1B71:11 |
Evaporator Temperature Sensor: Circuit Short To Ground |
GO to Pinpoint Test P |
| B1B71:15 |
Evaporator Temperature Sensor: Circuit Short To Battery Or Open |
GO to Pinpoint Test P |
| C1B14:11 |
Sensor Supply Voltage A: Circuit Short To Ground |
GO to Pinpoint Test H |
| C1B14:12 |
Sensor Supply Voltage A: Circuit Short To Battery |
GO to Pinpoint Test H |
| U0100:00 |
Lost Communication With ECM/PCM 'A': No Sub Type Information |
GO to Pinpoint Test U |
| U0140:00 |
Lost Communication With Body Control Module: No Sub Type Information |
GO to Pinpoint Test W |
| U0151:00 |
Lost Communication With Restraints Control Module: No Sub Type Information |
GO to Pinpoint Test X |
| U0155:00 |
Lost Communication With Instrument Panel Cluster (IPC) Control Module: No Sub Type Information |
GO to Pinpoint Test Y |
| U0253:00 |
Lost Communication With Accessory Protocol Interface Module: No Sub Type Information |
GO to Pinpoint Test AA |
| U0401:00 |
Invalid Data Received from ECM/PCM A: No Sub Type Information |
GO to Pinpoint Test AB |
| U0401:82 |
Invalid Data Received from ECM/PCM A: Alive/Sequence Counter Incorrect/Not Updated |
GO to Pinpoint Test AB |
| U0422:68 |
Invalid Data Received From Body Control Module: Event Information |
GO to Pinpoint Test AB |
| U0422:81 |
Invalid Data Received From Body Control Module: Invalid Serial Data Received |
GO to Pinpoint Test AB |
| U0452:82 |
Invalid Data Received From Restraints Control Module: Alive/Sequence Counter Incorrect/Not Updated |
GO to Pinpoint Test AB |
| U1000:00 |
Solid State Driver Protection Active -Driver Disabled: No Sub Type Information |
GO to Pinpoint Test AC |
| U2024:51 |
Control Module Cal-Config Data: Not Programmed |
GO to Pinpoint Test AD |
| U2100:00 |
Initial Configuration Not Complete: No Sub Type Information |
GO to Pinpoint Test AD |
| U3000:41 |
Control Module: General Checksum Failure |
GO to Pinpoint Test AE |
| U3000:49 |
Control Module: Internal Electronic Failure |
GO to Pinpoint Test AE |
| U3003:16 |
Battery Voltage: Circuit Voltage Below Threshold |
GO to Pinpoint Test AF |
| U3003:17 |
Battery Voltage: Circuit Voltage Above Threshold |
GO to Pinpoint Test AG |
| P0530:00 |
A/C Refrigerant Pressure Sensor 'A' Circuit: No Sub Type Information |
GO to Pinpoint Test AX |
| P2600:00 |
Coolant Pump 'A' Control Circuit/Open: No Sub Type Information |
GO to Pinpoint Test D |
| P2601:00 |
Coolant Pump 'A' Control Circuit Performance/Stuck Off: No Sub Type Information |
GO to Pinpoint Test D |
| P2602:00 |
Coolant Pump 'A' Control Circuit Low: No Sub Type Information |
GO to Pinpoint Test D |
| P2603:00 |
Coolant Pump 'A' Control Circuit High: No Sub Type Information |
GO to Pinpoint Test D |
| P2B86:00 |
Coolant Pump 'A' Overspeed/Air in System: No Sub Type Information |
GO to Pinpoint Test D |
| P2B87:00 |
Coolant Pump 'A' Underspeed: No Sub Type Information |
GO to Pinpoint Test D |
| P2B9C:00 |
Coolant Pump 'A' Stuck/Stalled: No Sub Type Information |
GO to Pinpoint Test D |
| P2B9D:00 |
Coolant Pump 'A' Supply Voltage Circuit: No Sub Type Information |
GO to Pinpoint Test D |
| P2B9E:00 |
Coolant Pump 'A' Control Module Overtemperature: No Sub Type Information |
GO to Pinpoint Test D |
| U0626:00 |
Lost Communication With A/C Refrigerant Pressure Sensor 'A': No Sub Type Information |
GO to Pinpoint Test AX |
| P0531:00 |
A/C Refrigerant Pressure Sensor 'A' Circuit Range/Performance: No Sub Type Information |
GO to Pinpoint Test AX |
| P0D6D:00 |
A/C Compressor 'A' Motor Voltage 'A' Low: No Sub Type Information |
GO to Pinpoint Test R |
| P0D6F:00 |
A/C Compressor 'A' Motor Current High: No Sub Type Information |
GO to Pinpoint Test R |
| P0D71:00 |
A/C Compressor Control Module Internal Temperature Sensor 'A' Performance: No Sub Type Information |
GO to Pinpoint Test R |
| P2611:00 |
A/C Refrigerant Distribution Valve 'A' Control Circuit/Open: No Sub Type Information |
GO to Pinpoint Test S |
| P2612:00 |
A/C Refrigerant Distribution Valve 'A' Control Circuit Low: No Sub Type Information |
GO to Pinpoint Test S |
| P2613:00 |
A/C Refrigerant Distribution Valve 'A' Control Circuit High: No Sub Type Information |
GO to Pinpoint Test S |
| P26FD:00 |
A/C Compressor 'A' Internal Control Module Performance: No Sub Type Information |
GO to Pinpoint Test R |
| P2D41:00 |
A/C Compressor 'A' Motor Voltage 'B' Performance: No Sub Type Information |
GO to Pinpoint Test R |
| P2D42:00 |
A/C Compressor 'A' Motor Voltage 'B' Low: No Sub Type Information |
GO to Pinpoint Test R |
| P2D44:00 |
A/C Compressor 'A' Motor Performance: No Sub Type Information |
GO to Pinpoint Test R |
| P2DA4:00 |
Coolant Heater 'A' Internal Control Module Performance: No Sub Type Information |
GO to Pinpoint Test AI |
| P2DA5:00 |
Coolant Heater 'A' Supply Voltage Circuit: No Sub Type Information |
GO to Pinpoint Test AI |
| P2DA6:00 |
Coolant Heater 'A' Over Temperature: No Sub Type Information |
GO to Pinpoint Test AJ |
| P2DA7:00 |
Coolant Heater 'A' Control Module System Voltage: No Sub Type Information |
GO to Pinpoint Test AI |
| P2F08:00 |
A/C Refrigerant Pressure Sensor 'C' Circuit: No Sub Type Information |
GO to Pinpoint Test AY |
| P2F09:00 |
A/C Refrigerant Pressure Sensor 'C' Circuit Range/Performance: No Sub Type Information |
GO to Pinpoint Test AY |
| U069E:81 |
Lost Communication with Coolant Heater 'B': Invalid Serial Data Received |
GO to Pinpoint Test AI |
| U069E:87 |
Lost Communication with Coolant Heater 'B': Missing Message |
GO to Pinpoint Test AI |
| U06AE:00 |
Lost Communication With A/C Refrigerant Pressure Sensor 'C': No Sub Type Information |
GO to Pinpoint Test AY |