Mike's Workshop Manuals: Service manuals for every vehicle
Home >> Ford >> 2021 >> Expedition SSV, RWD >> Repair and Diagnosis >> Quick Lookups >> DTC Index >> DTC Index (Acceleration Control - Exterior Lighting System) >> Exterior Lighting System DTCS >> Trailer Lamps >> TRM

Trailer Lamps: TRM

DTC Description Action
C1B14:11 Sensor Supply Voltage A: Circuit Short To Ground Refer to: Parking Aid .
C1B14:12 Sensor Supply Voltage A: Circuit Short To Battery Refer to: Parking Aid .
B10E8:4B Secondary Battery Relay "A": Over Temperature GO to Pinpoint Test F
B131E:12 Security Anti-Theft Alarm: Circuit Short To Battery Refer to: Perimeter Anti-Theft Alarm .
B1496:12 Trailer Backup Assist Input Sensor: Circuit Short To Battery Refer to: Parking Aid .
B1496:14 Trailer Backup Assist Input Sensor: Circuit Short To Ground or Open Refer to: Parking Aid .
B1D08:11 Left Trailer Direction Indicator: Circuit Short To Ground GO to Pinpoint Test B
B1D08:12 Left Trailer Direction Indicator: Circuit Short To Battery GO to Pinpoint Test C
B1D09:11 Right Trailer Direction Indicator: Circuit Short To Ground GO to Pinpoint Test B
B1D09:12 Right Trailer Direction Indicator: Circuit Short To Battery GO to Pinpoint Test C
U0140:00 Lost Communication With Body Control Module: No Sub Type Information GO to Pinpoint Test G
U1000:00 Solid State Driver Protection Active -Driver Disabled: No Sub Type Information The module has temporarily disabled an output because an excessive current draw exists (such as a short to ground). The TRM cannot enable the output until the cause of the short is corrected. ADDRESS all other Diagnostic Trouble Codes (DTCs) first. After the cause of the concern is corrected, CLEAR the Diagnostic Trouble Codes (DTCs). REPEAT the self-test.
U2100:00 Initial Configuration Not Complete: No Sub Type Information CHECK the vehicle service history for recent service actions related to this module. This DTC sets due to incomplete or incorrect PMI procedures. If there have been recent service actions with this module, REPEAT the PMI procedure as directed by the diagnostic scan tool. Refer to: Module Programming . If there have been no recent service actions, INSTALL a new TRM to correct the failure to retain configuration data.
U3000:49 Control Module: Internal Electronic Failure The module has permanently disabled an output because an excessive current draw fault (such as a short to ground) has exceeded the limits that the TRM can withstand. The cause of the excessive current draw MUST be corrected before a new TRM is installed. ADDRESS all other Diagnostic Trouble Codes (DTCs) first. After the cause of the concern is corrected, INSTALL a new TRM.