P1013 - WASTEGATE Control Pressure Sensor Circuit High
DTC DESCRIPTION P1013 - WASTEGATE CONTROL PRESSURE SENSOR CIRCUIT HIGH
| Description: | This DTC sets when the wastegate vacuum sensor reading is greater than a calibrated threshold and the fault timer has exceeded the calibrated time threshold indicating an open circuit or a short to voltage. | ||
| Possible Causes: |
|
||
| Diagnostic Aids: | The typical maximum threshold is 4.93 V and time threshold is 5 seconds. | ||
| Application | Key On Engine Off | Key On Engine Running | Continuous Memory |
| All | GO to Pinpoint Test HN. | ||