| B11DB:02 |
Battery Monitoring Module "A": General Signal Failure |
GO to Pinpoint Test G |
| B11DB:08 |
Battery Monitoring Module "A": Bus Signal/Message Failures |
GO to Pinpoint Test G |
| B11DB:09 |
Battery Monitoring Module "A": Component Failures |
GO to Pinpoint Test G |
| B11DB:11 |
Battery Monitoring Module "A": Circuit Short To Ground |
GO to Pinpoint Test G |
| B11DB:49 |
Battery Monitoring Module "A": Internal Electronic Failure |
GO to Pinpoint Test N |
| B11DB:55 |
Battery Monitoring Module "A": Not Configured |
GO to Pinpoint Test O |
| B11DB:9A |
Battery Monitoring Module "A": Component or System Operating Conditions |
GO to Pinpoint Test G |
| B1489:11 |
Battery Monitoring System (BMS) Sensor Power: Circuit Short To Ground |
GO to Pinpoint Test G |
| B130C:12 |
Load Shed Control: Circuit short To Battery |
GO to Pinpoint Test G |
| B130C:14 |
Load Shed Control: Circuit short To Ground or Open |
GO to Pinpoint Test G |
| B1438:03 |
Battery Current Sensor: FM / PWM |
GO to Pinpoint Test G |
| B11D9:16 |
Vehicle battery - circuit voltage below threshold |
GO to Pinpoint Test B |
| B11D9:17 |
Vehicle battery - circuit voltage above threshold |
GO to Pinpoint Test A |
| B1513:06 |
Vehicle battery"B": Component Failure |
If combined with B11D9:16, GO to Pinpoint Test B
If combined with B11D9:17, GO to Pinpoint Test A |
| P0562:00 |
System Voltage Low: No Sub Type Information |
GO to Pinpoint Test B |
| P0563:00 |
System Voltage High: No Sub Type Information |
GO to Pinpoint Test A |
| P065B:00 |
Generator "A" Control Circuit Range/Performance: No Sub Type Information |
GO to Pinpoint Test B |
| P065C:00 |
Generator "A" Mechanical Performance: No Sub Type Information |
GO to Pinpoint Test B |
| P0A3B:00 |
Generator "A" Over Temperature: No Sub Type Information |
GO to Pinpoint Test M |
| P0A5A:00 |
Generator Current Sensor Circuit Range/Performance: No Sub Type Information |
GO to Pinpoint Test F |
| P0A5B:00 |
Generator Current Sensor Circuit Low: No Sub Type Information |
GO to Pinpoint Test F |
| P0A5C:00 |
Generator Current Sensor Circuit High: No Sub Type Information |
GO to Pinpoint Test F |
| P1397 |
System Voltage Out Of Self Test Range |
If combined with P0562, GO to Pinpoint Test B
If combined with P0563, GO to Pinpoint Test A |
| P2D57 |
Generator "B" Control Circuit Range/Performance |
GO to Pinpoint Test L |
| P2D58 |
Generator "B" Mechanical Performance |
GO to Pinpoint Test J |
| P2D59 |
Generator "B" Over Temperature |
GO to Pinpoint Test K |
| U012D:00 |
Lost Communication With Generator "A" Control Module: No Sub Type Information |
GO to Pinpoint Test H |
| U012F :00 |
Lost Communication With Generator "B" Control Module |
GO to Pinpoint Test I |
| U042E:00 |
Invalid Data Received From Generator "A" Control Module: No Sub Type Information |
GO to Pinpoint Test H |
| U044D |
Invalid Data Received From Generator "B" Control Module |
GO to Pinpoint Test I |
| All Other DTCs |
-- |
REFER to: Electronic Engine Controls
. |
| All Other DTCs |
-- |