Pinpoint Tests: Notes
Both Exterior Mirrors Are Inoperative
Refer to Power Mirrors for schematic and connector information.
Normal Operation and Fault Conditions
BJB fuse 6 (10A) supplies voltage to the exterior mirror control switch when the ignition is ON. The exterior mirror control switch supplies voltage and ground to the exterior mirror motors based on switch inputs.
Possible Sources
- Fuse
- Wiring, terminals or connectors
- Exterior mirror control switch (integral to the LH front window control switch)
Visual Inspection and Diagnostic Pre-Checks
Inspect BJB fuse 6 (10A).