DTC P0460 - Fuel Level Sensor A Circuit
DTC DESCRIPTION P0460 - FUEL LEVEL SENSOR A CIRCUIT
| Description: This DTC sets when the PCM calculates the amount of fuel used during operation does not change or does not correspond with the calculated fuel usage. | |||
Possible Causes:
|
|||
| Diagnostic Aids: Check with the customer for driving and fueling habits that would keep the fuel level at approximately the same value. Monitor the FLI PID while attempting to move the fuel level float by adding or removing fuel as necessary. | |||
| Application | Key On Engine Off | Key On Engine Running | Continuous Memory |
| All | GO to PINPOINT TEST HX . | ||