BCM and PCM
Diagnostics in this service information assume a certain skill level and knowledge of Ford-specific diagnostic practices. REFER to: DIAGNOSTIC METHODS .
| DTC | Description | Action |
|---|---|---|
| B11DB:02 | Battery Monitoring Module "A": General Signal Failure | GO to Pinpoint Test E |
| B11DB:08 | Battery Monitoring Module "A": Bus Signal / Message Failure | GO to Pinpoint Test E |
| B11DB:09 | Battery Monitoring Module "A": Component Failure | GO to Pinpoint Test E |
| B11DB:11 | Battery Monitoring Module "A": Circuit Short To Ground | GO to Pinpoint Test E |
| B11DB:49 | Battery Monitoring Module "A": Internal Electronic Failure | GO to PINPOINT TEST K |
| B11DB:55 | Battery Monitoring Module "A": Not Configured | GO to PINPOINT TEST L |
| B11DB:9A | Battery Monitoring Module "A": Component or System Operating Conditions | GO to Pinpoint Test E |
| B1489:11 | Battery Monitoring System (BMS) Sensor Power Circuit Short To Ground | GO to Pinpoint Test E |
| P0562:00 | System Voltage Low: No Sub Type Information | GO to PINPOINT TEST B |
| P0563:00 | System Voltage High: No Sub Type Information | GO to PINPOINT TEST A |
| P0620:00 | Generator Control Circuit: No Sub Type Information | GO to PINPOINT TEST G |
| P0625:00 | Generator Field/F Terminal Circuit Low: No Sub Type Information | GO to Pinpoint Test H |
| P0626:00 | Generator Field/F Terminal Circuit High: No Sub Type Information | GO to Pinpoint Test H |
| P065B:00 | Generator "A" Control Circuit Range/Performance: No Sub Type Information | GO to PINPOINT TEST B |
| P065B:00 | Generator Control Circuit Range/Performance: No Sub Type Information | GO to PINPOINT TEST G |
| P0A5A:00 | Generator Current Sensor Circuit Range/Performance: No Sub Type Information | GO to PINPOINT TEST F |
| P0A5B:00 | Generator Current Sensor Circuit Low: No Sub Type Information | GO to PINPOINT TEST F |
| P0A5C:00 | Generator Current Sensor Circuit High: No Sub Type Information | GO to PINPOINT TEST F |
| DTC | Description | Action |
|---|---|---|
| B11DB:02 | Battery Monitoring Module "A": General Signal Failure | GO to Pinpoint Test E |
| B11DB:08 | Battery Monitoring Module "A": Bus Signal / Message Failure | GO to Pinpoint Test E |
| B11DB:09 | Battery Monitoring Module "A": Component Failure | GO to Pinpoint Test E |
| B11DB:11 | Battery Monitoring Module "A": Circuit Short To Ground | GO to Pinpoint Test E |
| B11DB:49 | Battery Monitoring Module "A": Internal Electronic Failure | GO to PINPOINT TEST K |
| B11DB:55 | Battery Monitoring Module "A": Not Configured | GO to PINPOINT TEST L |
| B11DB:9A | Battery Monitoring Module "A": Component or System Operating Conditions | GO to Pinpoint Test E |
| B1489:11 | Battery Monitoring System (BMS) Sensor Power Circuit Short To Ground | GO to Pinpoint Test E |
| P0562 | System Voltage Low | GO to PINPOINT TEST B |
| P0563 | System Voltage High | GO to PINPOINT TEST A |
| P0620 | Generator Control Circuit | GO to PINPOINT TEST G |
| P0625 | Generator Field/F Terminal Circuit Low | GO to Pinpoint Test H |
| P0626 | Generator Field/F Terminal Circuit High | GO to Pinpoint Test H |
| P065B | Generator Control Circuit Range/Performance | GO to PINPOINT TEST G |
| P0A5A | Generator Current Sensor Circuit Range/Performance | GO to PINPOINT TEST F |
| P0A5B | Generator Current Sensor Circuit Low | GO to PINPOINT TEST F |
| P0A5C | Generator Current Sensor Circuit High | GO to PINPOINT TEST F |
| P1397 | System Voltage Out Of Self-Test Range | GO to PINPOINT TEST F If combined with P0562, GO to PINPOINT TEST B If combined with P0563, GO to PINPOINT TEST A |