Typical Diagnostic Reference Values
WARNING: This page is about a different variant/trim than selected.
| Inputs |
Component/PID Only |
Measured/PID Values |
Units Measured/PID |
| KOEO |
Hot Idle |
48 KM/H (30 MPH) |
89 KM/H (55 MPH) |
| APP |
APP Sensor |
0 |
0 |
18 |
23.5 |
% |
| APP2 |
APP Sensor |
0.39 |
0.39 |
0.49 |
0.92 |
VOLTS |
| APP_MAXDIFF |
PID |
0 |
0 |
0 |
-0.06 |
DEG |
| B+ |
PID |
12.7 |
13-14 |
13-14 |
13-14 |
VOLTS |
| BARO |
PID |
14.35/155.2 |
14.35/155.2 |
14.35/155.2 |
14.35/155.2 |
PSI/Hz |
| BOO |
BPP Switch |
OFF |
ON (E) |
OFF |
OFF |
ON/OFF |
| ECT |
ECT Sensor |
3.27/105 (221) |
3.51/97 (206.6) |
3.9/84 (183.2) |
3.78/88 (190.4) |
VOLTS/DEG C (DEG F) |
| HTRCM11 |
HO2S11 Sensor |
1.65 |
1.65 |
1.65 |
1.48 |
AMPS |
| HTRCM12 |
HO2S12 Sensor |
615 |
615 |
615 |
622 |
mA |
| IAT |
IAT Sensor |
1.27/62 (143.6) |
1.79/49 (120.2) |
3.42/16 (60.8) |
4.04/2 (35.6) |
VOLTS/DEG C (DEG F) |
| LOAD |
PID |
0 (I) |
27.45 |
29.41 |
44.31 |
% |
| LONGFT1 |
PID |
(I) |
-20 TO +20 |
-20 TO +20 |
-20 TO +20 |
% |
| MAP |
MAP Sensor |
4.02/98.93/14.35/29.2 |
1.25/30.95/4.49/9.2 |
2.52/61.98/8.99/17.8 |
2.32/51.98/7.54/15.4 |
VOLTS/kPa/PSI/inHg |
| MISFIRE |
PID |
NO |
NO |
NO |
NO |
YES/NO |
| MP_LRN |
PID |
NO |
NO |
NO |
NO |
YES/NO |
| O2BANK1 |
PID |
VARIES |
VARIES |
VARIES |
VARIES |
RICH/LEAN |
| O2S11 |
HO2S11 Sensor |
(I) |
switching (C) |
switching (C) |
switching (C) |
VOLTS |
| O2S12 |
HO2S12 Sensor |
(I) |
(D) |
(D) |
(D) |
VOLTS |
| RPM |
CKP Sensor |
0 |
698.3 |
1918 |
1807 |
RPM |
| SHRTFT1 |
PID |
(I) |
-10 TO +10 |
-10 TO +10 |
-10 TO +10 |
% |
| SYNC |
PID |
NO |
YES |
YES |
YES |
YES/NO |
| VSS |
PID |
0 |
0 |
48 km/h (30 MPH) |
89 km/h (55 MPH) |
km/h/MPH |
| Outputs |
Component/PID Only |
Measured/PID Values |
Units Measured/PID |
| KOEO |
Hot Idle |
48 KM/H (30 MPH) |
89 KM/H (55 MPH) |
| EVAPCP |
EVAPCP Valve |
OFF |
OFF |
ON |
ON |
ON/OFF |
| FP |
Fuel Pump Control Module |
OFF |
ON |
ON |
ON |
ON/OFF |
| FUELSYS |
PID |
OPEN LOOP |
CLOSED LOOP |
CLOSED LOOP |
CLOSED LOOP |
OPEN/CLOSED LOOP |
| HFC |
PID |
OFF |
ON (B) |
OFF |
OFF |
ON/OFF |
| HTR11 |
HO2S11 Sensor |
OFF |
ON |
ON |
ON |
ON/OFF |
| HTR12 |
HO2S12 Sensor |
OFF |
ON |
ON |
ON |
ON/OFF |
| IMRC |
IMRC Solenoid |
OFF |
ON |
ON |
ON |
ON/OFF |
| IMTV |
IMTV Solenoid |
OFF |
ON |
ON |
ON |
ON/OFF |
| LFC |
PID |
OFF |
ON (B) |
OFF |
OFF |
ON/OFF |
| SPARKADV |
PID |
10 |
10.25 |
39 |
27.25 |
DEG |
| Other |
Component/PID Only |
Measured/PID Values |
Units Measured/PID |
| KOEO |
Hot Idle |
48 KM/H (30 MPH) |
89 KM/H (55 MPH) |
| VPWR |
PID |
12.52 |
13-14 |
13-14 |
13-14 |
VOLTS |
| VREF |
PID |
5 |
5 |
5 |
5 |
VOLTS |