Spring Lock Couplings
Special Tool(s) / General Equipment
| 310-S039 Disconnect Tool, Spring Lock Coupling |
- If servicing a liquid fuel tube spring lock coupling, release the fuel system pressure.
Refer to: Fuel System Pressure Release .
- Disconnect the battery ground cable.
Refer to: Battery Cables - 2.0L Duratec-HE ( BATTERY CABLES - 2.0L DURATEC-HE ).
- Install the Spring Lock Coupling Disconnect Tool on the tube and push into the spring lock coupling to release.
Special Tool(s) : 310-S039 (Disconnect Tool, Spring Lock Coupling)
- Separate the spring lock coupling from the tube.
- Align and push the spring lock coupling onto the tube until fully seated.
- Pull on the coupling to make sure it is fully engaged.
- Connect the battery ground cable.