Mike's Workshop Manuals: Service manuals for every vehicle
Home >> Ford >> 2012 >> Econoline Base, Van Cargo >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 75 (HVAC - Climate Control System) >> Description And Operation >> Air Conditioning >> Refrigerant System Dye

Refrigerant System Dye

WARNING: This page is about a different variant/trim than selected.

Fluorescent refrigerant system dye is added to the refrigerant system at the factory to assist in refrigerant system leak diagnosis using a Rotunda-approved ultraviolet blacklight. It is not necessary to add additional dye to the refrigerant system before diagnosing leaks, even if a significant amount of refrigerant has been removed from the system. New suction accumulators are shipped with a fluorescent dye "wafer" included in the desiccant bag which will dissolve after approximately 30 minutes of continued A/C operation. It is not necessary to add dye after flushing or filtering the refrigerant system because a new suction accumulator is installed as part of the flushing or filtering procedure. Additional refrigerant system dye should only be added if more than 50% of the refrigerant system lubricant capacity has been lost due to a fitting separation, hose rupture or other damage. Refer to CLIMATE CONTROL SYSTEM - GENERAL INFORMATION AND DIAGNOSTICS .