- Unable to duplicate the customer concern and no DTCs present
|
- Incorrect functioning of the HVAC system and/or related components
|
|
|
|
- Wiring, terminals or connectors
- PCM
- Function selector switch
- A/C clutch relay
- A/C compressor clutch air gap
- Blower motor resistor
- Blower motor switch
|
|
- Incorrect/erratic direction of airflow from outlets
|
- Function selector switch
- Vacuum hose/harness
- Vacuum control motor
- A/C vacuum check valve
- Vacuum reservoir tank
- Air distribution door/linkage
|
|
- Insufficient, erratic or no heat
|
- Low engine coolant level
- Engine overheating
- Plugged or partially plugged heater core
- Temperature blend door binding/stuck
- Temperature blend door actuator
|
|
- The air conditioning (A/C) is inoperative
|
- Fuse(s)
- Wiring, terminals or connectors
- A/C cycling switch
- Low refrigerant system charge
- Function selector switch
- A/C high pressure switch
- A/C clutch relay
- PCM
- A/C compressor clutch air gap
- A/C compressor clutch field coil
|
|
- The air conditioning (A/C) is always on - A/C compressor does not cycle
|
- Wiring, terminals or connectors
- Function selector switch
- A/C clutch relay
- PCM
- A/C compressor clutch air gap
|
|
- The air conditioning (A/C) is always on - A/C mode always commanded ON
|
- Wiring, terminals or connectors
- Function selector switch
- A/C clutch relay
- PCM
- A/C compressor clutch air gap
|
|
- Insufficient air conditioning (A/C) cooling - auxiliary system
|
- Thermostatic Expansion Valve (TXV)
- Leaking or restricted vacuum hose
- Vacuum control motor
- Stuck or bound linkage or door
|
|
- Temperature control is inoperative/does not operate correctly
|
- Fuse(s)
- Wiring, terminals or connectors
- Temperature blend door actuator
- Temperature control potentiometer
- Stuck or bound linkage or door
|
|
- The blower motor is inoperative
|
- Fuse(s)
- Wiring, terminals or connectors
- Blower motor relay
- Function selector switch
- Blower motor
|
|
- The blower motor does not operate correctly
|
- Wiring, terminals or connectors
- Blower motor resistor
- Blower motor switch
|
|
- The auxiliary blower motor is inoperative
|
- Fuse(s)
- Wiring, terminals or connectors
- Auxiliary blower motor relay
- Auxiliary blower motor switch
- Auxiliary high speed blower motor relay
- Auxiliary blower motor
- Auxiliary blower motor resistor
- Function selector switch
|
|
- The auxiliary blower motor does not operate correctly
|
- Wiring, terminals or connectors
- Auxiliary blower motor resistor
- Auxiliary blower motor switch
- Auxiliary blower motor relay
- Auxiliary high speed blower motor relay
|
|
- The auxiliary temperature/mode is inoperative/does not operate correctly
|
- Auxiliary temperature actuator
- Auxiliary mode actuator
- Auxiliary vacuum source line
|
- If both temperature and mode are affected, REPAIR the vacuum source line for an obstruction or leak. TEST the system for normal operation.
- If the temperature or mode alone are affected, INSPECT the temperature or mode door for a binding or broken condition. If no condition is found, INSTALL a new actuator. TEST the system for normal operation.
|
- A/C pressure relief valve discharging
|
- High system pressure
- A/C pressure relief valve
|
- CHECK the high side system pressure. If the pressure is below the A/C pressure relief valve open pressure, INSTALL a new A/C pressure relief valve. If the system pressure is above the A/C pressure relief valve open pressure, REPAIR the system for a restriction.
|