Vehicles with IA

Load shed only occurs when the engine is not running, and the ignition is in the ACC, RUN or delayed accessory mode. To clear the load shed state, restart the engine. If the ignition is in RUN and load shed occurs, the audio system turns off and the ignition remains in RUN. If the ignition is in ACC and load shed occurs, the audio system mutes for 1 minute then the ignition mode changes to OFF. For example, if equipped, the memory seats move to the easy exit position and the dome light may illuminate.

If a fault occurs with the battery current sensor or circuits, the only load shed strategy is a 45 minute timer. After 45 minutes have elapsed, the audio system turns off. To clear the load shed state, restart the engine.